Produces a series of 4 timed pulses upon receipt of an input pulse.
Inputs:
Yellow LED (Logical): A clock pulses at this input generates a new set of output pulses.
T1, T2, T3 (Time Values): Sets the delay time in ticks for the T1-T3 outputs. T0 delay is always 0.
PW (Pulse Width Value): Sets the On time in ticks for each of the output pulses.
Logical Outputs:
Arp X T0: A pulse is produced at this output, with no delay, when
the module receives a pulse at the clock input. It is the same as the input
pulse, except the pulse duration is set to PW ticks.
Arp X T1-T3:
Clock pulses produced after their respective delay times, as set by the T1-T3
inputs. Duration On is the same for all outputs, as set by the PW input. Yellow
output LEDS flash to indicate the output status.
Arp X TA: A series
of all 4 pulses, the logical OR of T0-T3.
BankStep is Copyright © 2001-2004 by John Dunn and Algorithmic Arts. All Rights Reserved.